Metal Clad Switchgears

All parts are separated to each other with metal plate. Cell carcasses are manufactured for 2-3mm powder coated galvanized steel. Other metal parts used in the manufacture of cell electro-galvanized coating. Rear and upper surfaces of the cells occurs fully bolted closures . Cells consist of four parts .

1-Low Voltage (LV) Part

2-Busbar Part

3-Cable Part

4-Circuit breaker Part

Low Voltage (LV) Part : It is in  the front of the cell which is in measure protection part and  control equipment. Relays, ammeter, voltmeter, wattmeter measuring instruments such as the energy analyzer is kept in this section. Mimic diagrams are located in the leading edge.

Busbar Parts: It is  the upper section of the rear of the cell. It includes Electrolytic copper busbars with rectangular cross-section that connects the cells and circuit breaker connection. All busbar ends can provide opportunity for expansion of any structure can be assembled without the need for renovation.

Cable section: It is at the bottom of the back of the cell. Current transformers, voltage transformers, surge arresters, ground circuit breaker, a capacitive voltage divider, post insulators and wiring terminals located in this section.

Circuit breaker Part : It is in  the front of the cell. Switching element, the circuit breaker (SF6 or vacuum type circuit breaker type) and circuit breaker the part where its wheels are located. Insurance, depending on the project, the contactor are also located in this section. Breaking mechanism is fitted on the trolley system. The structure features a slide-out for easy and quick to act ..

Drawer positions: Business location: The switching units, the main circuit connection part is provided in full. Energized circuit breaker, circuit breaker truck is connected to the grounding system of the cell.

Test location: drawer is in position of pulled back.

No longer have a connection between the main circuit switching unit. Situated on the pull-out section of the connection of low voltage switching equipment is still available. Metal valves are closed. Out of the position: pull-out was completely out of the cell. No connection between the cell and the drawers are all gone.

Technical Specification:

Operation  Voltage

kV

3,6

7,2

12

17,5

24

36

40,5

Withstand impulse voltage

kV

10

20

28

38

50

70

85

Withstand impulse voltage with network frequency

kV

40

60

75

95

125

170

190

Rated Current

A

400-630-800-1250-2000-2500-3150-4000

Withstand Short-circuit

kA

16-25-31.5-40-50 1 or 3 sec

Peak Current

kA

40-50-63-80-100-125

Frequency

Hz

50/60

Minimum ambient temperature

§C

-5

Maximum ambient temperature

§C

40

Maximum moisture

%

80

Protection Type

IP 3X(door close)- IP 2X(door open)

The Dimensions of Metal Clad

Cubicle types with vacuum circuit breaker

1-24 kV

36-40.5 kV

mm

Width

Length

Height

depth

Length

height

Incoming/outgoing cubicle with circuit breaker

800

2000

2100

1200

3000

2300

Transformer protection cubicle with circuit breaker

800

2000

2100

1200

3000

2300

Incoming/outgoing cubicle with voltage transformer and circuit breaker

800

2000

2100

1200

3000

2300

Transformer protection cubicle with voltage transformer and circuit breaker

800

2000

2100

1200

3000

2300

Current voltage measurement cubicle

800

2000

2100

1200

3000

2300

Voltage transformer cubicle

800

2000

2100

1200

3000

2300

Busbar raising cubicle

500

2000

2100

600

3000

2300

Cable connection cubicle

800

2000

2100

1200

3000

2300

Busbar connection coupling cubicle with circuit breaker

1600

2000

2100

2400

3000

2300

Busbar separator cubicle with circuit breaker

800

2000

2100

1200

3000

2300

Motor cubicle

800

2000

2100

1200

3000

2300

Capacitor Cubicle

800

2000

2100

1200

3000

2300

 

SF6 gas insulated cubicle types with circuit breaker

1-24 kV

36-40.5 kV

mm

width

length

height

depth

length

height

Incoming/outgoing cubicle with circuit breaker

1100

2350

2100

1400

3000

2300

Transformer protection cubicle with circuit breaker

1100

2350

2100

1400

3000

2300

Incoming/outgoing cubicle with voltage transformer and circuit breaker

1100

2350

2100

1400

3000

2300

Transformer protection cubicle with voltage transformer and circuit breaker

1100

2350

2100

1400

3000

2300

Current voltage measurement cubicle

1100

2350

2100

1400

3000

2300

Voltage Transformer cubicle

1100

2350

2100

1400

3000

2300

Busbar raising cubicle

500

2350

2100

600

3000

2300

Cable connection cubicle

800

2350

2100

1200

3000

2300

Busbar connection coupling cubicle with circuit breaker

2200

2350

2100

2800

3000

2300

Busbar separator cubicle

1100

2350

2100

1400

3000

2300

Motor Cubicle

1100

2350

2100

1400

3000

2300

Capacitor Bank Cubicle

1100

2350

2100

1400

3000

2300

 

  • While the cutter is cutting off his car cannot intervene.
  • Position of the cutter out of service or the test cannot be off.
  • Cutting service position cannot be opened the cell door.
  • When the circuit breaker cannot be off the cell door.
  • Cannot interfere with the grounding position, the blade of the cutter trolley service.
  • Grounding a closed position cutting blade cannot intervene in his car.

 




12 11 - 25
[1]

General Specification
They are used to protect the line. Protection is made with current transformer, relay, and circuit breaker . When the circuit breaker is on the set...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Are used to protect the transformer. Current transformer, relay, circuit breaker and protection is made. When the circuit breaker on the set of val...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Are used to protect the transformer. Current transformer, relay, circuit breaker and protection is made. When the circuit breaker on the set of val...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Are used to protect the transformer. Current transformer, relay, circuit breaker and protection is made. When the circuit breaker on the set of val...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Is used to make the net measurement. Placed before the location which is desired to measure. Content: Busbar: copper units of equipment that can ...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Measure the voltage on the line with voltage transformers. Content: Busbar: copper units of equipment that can connect to each other. Earthing s...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Is used for raising the busbar. Content: Busbars: copper units of equipment that can connect to each other.
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
To connect the cable with the busbars. Contents: Busbar: copper units of equipment that can connect to each other. Voltage Indicators: Power cab...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Coupling the power supply to more than one transformer is used to determine the priority of transformers centers. Contents: Busbar: copper units ...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Is used to divide the main busbars with protection. Rarely used. Contents: Busbar: copper units of equipment that can connect to each other. Ear...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
It is used for protect the motor. Protection is made by current transformer, relay, circuit breaker. When the circuit breaker is  on the set of va...
Metal Clad Switchgears Fiyat? sorunuz!

General Specification
Capacitors are used to protect. Protection is made by current transformer, relay, circuit breaker . When the circuit breakers on the set of values ...
Metal Clad Switchgears Fiyat? sorunuz!